Stojanovska, Zdenka and Zunic, Zora S. and Bossew, Peter and Bochicchio, Francesco and Carpentieri, Carmela and Venoso, Gennaro and Mishra, Rosaline and Rout, R.P. and Sapra, B.K. and Burghele, Bety D. and Cucos-Dinu, Alexandra and Boev, Blazo and Januseski, Jovan and Cosma, Constantin (2014) Preliminary results from time integrated measurements concentrations of indoor radon, thoron and their progenies in schools of Republic of Macedonia. Radiation Protection Dosimetry, 1-2 (162). pp. 152-156. ISSN 0144-8420

[thumbnail of Abstracts SEERAS 2014 Stojanovska et al.pdf]
Preview
Text
Abstracts SEERAS 2014 Stojanovska et al.pdf

Download (229kB) | Preview
[thumbnail of Doc13.pdf]
Preview
Text
Doc13.pdf

Download (117kB) | Preview

Abstract

The results presented here are part of a survey on concentrations of radon, thoron and their
progeny in different indoor environment of the Balkan region involving international
collaboration. This paper presents the preliminary measurement results obtained in 43 schools of
5 municipalities in the Republic of Macedonia. The time-integrated radon and thoron gas
concentrations were measured by CR-39 (placed in two chambers with different diffusion
barrier), whereas the radon progeny and thoron progeny concentration (EECR and EECT) were
measured by LR-115 nuclear track detectors based Direct Progeny Sensors (DTPS and DRPS).
The detectors were deployed at least 0.5 m distance away from the walls as well as away from
windows and doors, in order to minimize the thoron concentration variations, and exposed over
three-month period (March–May 2012).
The geometric mean values (and geometric standard deviations) of radon and thoron
concentrations, EERC and EETC were: 76 Bq/m3 (1.7), 12 Bq/m3 (2.3), 27 Bq/m3 (1.4), 0.75
Bq/m3 (2.5), respectively. Equilibrium factors between radon and its progeny (FRn) and thoron
and its progeny (FTn) were evaluated: FRn ranges from 0.10 to 0.84 and FTn ranges from 0.003 to
0.998 with geometric means (and geometric standard deviations) equal to 0.36 (1.71) and 0.07
(3.42), respectively. The linear regression analysis showed not significant correlation between the
measured quantities. While the means appear plausible and well in line with values reported in
literature, this is not so for some individual values. We discuss the technique and possible sources
of errors and uncertainties.