Stefanovski, Dejan and Anastasova, Liljana and Petkovska, Rumenka and Petrushevska-Tozi, Lidija and Arsova-Sarafinovska, Zorica (2025) Method performance verification and measurement uncertainty evaluation for determination of total active matter content in shampoos. Macedonian Pharmaceutical Bulletin, 71 (1). pp. 63-70. ISSN 1857-8969
![Dejan_Stefanovski.pdf [thumbnail of Dejan_Stefanovski.pdf]](https://eprints.ugd.edu.mk/style/images/fileicons/text.png)
Dejan_Stefanovski.pdf - Published Version
Download (366kB)
Abstract
The aim of our study was to perform in-use method verification of the standard ISO 6842:1989(E) method for determination of total active matter (TAM) content in shampoos. The method was verified for accuracy and precision (method precision, repeatability, and intermediate precision). To assure quality, measurement uncertainty was also estimated, through evaluation of the possible sources of uncertainty, using the Nordtest approach.
The obtained results for the accuracy, repeatability (method precision) and intermediate precision confirmed that the standard method could be successfully applied when compared to data for repeatability and intermediate precision provided in ISO 6842:1989(E) method. Measurement uncertainty was estimated for each measurement. The verified method was successfully applied for routine determination of total active matter content in shampoos.
Item Type: | Article |
---|---|
Subjects: | Medical and Health Sciences > Other medical sciences |
Divisions: | Faculty of Medical Science |
Depositing User: | Zorica Arsova Sarafinovska |
Date Deposited: | 12 Sep 2025 06:55 |
Last Modified: | 12 Sep 2025 06:55 |
URI: | https://eprints.ugd.edu.mk/id/eprint/36362 |